Description
BEA MATRIX FAMILY Loop Detectors – Single Unit
BEA MATRIX FAMILY Loop Detectors – Single Unit
UL Listed Loop Detectors – Single Unit with Yellow Housing
BEA’s MATRIX FAMILY of induction loop detectors are designed for vehicle detection applications in industrial environments.
These UL 508-listed loop detectors offer a wide range of features including automatic boost sensitivity (ABS), pulse on entry, and pulse on exit. MATRIX 3 provides learn on power up, as well as an independent dual loop detection setting.
The MATRIX FAMILY includes single and dual loop detectors with operating voltages of 110 – 120 VAC or 12 – 24 VAC / VDC, depending on the model.
Features
- Two Loop models available – Available in single or dual loop models
- Dual Outputs – Two relay outputs
- Vehicle detection, direction, and counting – Ideal for vehicle directionality and sequencing applications.
- Easy to adjust – Settings are adjusted via two potentiometers.
Specifications
- Tuning: Automatic
- Connector: 11-pin male (86CP11)
- Presence Time: 1 min – infinity
- Pulse Time Output: 100 ms or 500 ms
- LED Indicators
- Green: Power
- Red: Loop Status 1 / Loop Status 2
- Frequency Range: 20 kHz – 130 kHz
- Frequency Steps
- Single Loop: 4
- Double Loop: 2 (for each loop)
- Sensitivity (ΔL/L): 0.005 – 0.5%
- Reaction Time
- Single Loop: 25 ms
- Double Loop: 50 ms (each channel)
- Setup Time After Configuration: 2 s max by channel
- Power Supply (depending on model): 12 – 24 AC / DC ±10% ; 115 VAC ±10%
- Power Frequency: 48 – 62 Hz
- Power Consumption: < 2.5 W
- Temperature Range: -22 – 158 °F (-30 – 70 °C)
- Protections
- Loop Insulation Transformer
- Zener Diodes
- Gas Discharge Clamping
- Inductance Range: 20 – 1000 μH
- Connection: 86CP11 (Standard 11-pin Round)
- Relay Outputs: 2 (free potential change-over contact)
- Max. Contact Voltage: 230 VAC
- Max. Contact Current: 5 A (resistive)
- Setup Time at Power On
- MATRIXD/S: 8 s max by channel
- MATRIXIIS: 8 s max by channel
- MATRIX-3S: 1.6 s max by channel
- MATRIX-3D: 2.2 s max by channel
- Norm Conformity
- R&TTE: 1999 / 5 / EC
- EMC: 89 / 336 / EEC
- EMC: 89 / 336 / EE
- EMC: 2004 / 108 / EC
- FCC: 47 CFR 15
- IC: RSS-210 ISSUE 5
- UL Listed equipment for UL 508
- Degree of Protection: IP40
- Weight: 7 oz
- Dimensions: 1 1/2” (W) × 3” (H) × 3” (D)
Product Literature
- BEA MATRIX Cutsheet
- BEA MATRIX User Guide