EMX Plug-In Style Vehicle Loop Detector | EMX-ULT-PLG
EMX Plug-In Style Vehicle Loop Detector | EMX-ULT-PLG
The ULTRALOOP® plug-in vehicle loop detector combines small size with the full-featured functionality of the standard ULTRALOOP® product line in a plug-in module.
The ULT-PLG provides a solid-state output indicating vehicle presence. A second output can be used for presence, loop fault or pulse on entry/exit. The detector provides options for automatic sensitivity boost (ASB), fail-safe/ fail-secure, infinite/normal (5 min.) presence and the DETECT-ON-STOP™ or (DOS®) feature. DOS® will allow detection only when a vehicle has come to a complete stop on the loop. This EMX exclusive feature is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-PLG is easily installed and has user-friendly features that simplify set-up, operation and troubleshooting. Sensitivity selection is simplified by the ULTRAMETER™ display that indicates the appropriate sensitivity setting for the vehicle positioned on the loop. The 10 sensitivity settings allow for finer adjustment of the detection level, while the 4 frequency selections provide greater flexibility in preventing crosstalk in multi-loop applications.
Features
- Easy to install and set up with the ULTRAMETER sensitivity display
- Ignores cross traffic in tight spaces with DETECT-ON-STOP feature
- Compatible with many gate operators
- Frequency count/reset switch
- 10 sensitivity settings
- Loop diagnostics
- 4 operating frequencies
- Solid-state output
- Second output, pulse entry/exit, normal/infinite presence
- CE compliant
Manufacturer’s Warranty
- 2 Years
Technical Specifications
- Sensitivity: 10 levels, 0-9
- UltraMETER display: Indicates optimum sensitivity level, 0-9 diagnostic aid
- Loop frequency: 4 settings (low, med-low, med-hi, high)
- Loop inductance: 20…2000µH (Q factor > 5)
- Grounded loop: Isolation transformer allows operation with poor quality loops
- Automatic tuning: Detector tunes to loop on power-up and following frequency count function
- Environmental tracking: Automatic compensation
- Surge protection: Loop circuitry protected by surge suppressors
- Detect output: Solid-state (open collector)
- Output B: Solid-state (open collector)
- Output B inverted: Solid-state (open collector)
- Power / loop fault indicator: Green LED
- Detect / frequency count indicator: Red LED
- Detect-on-Stop: Requires vehicle to stop for a minimum of 1 second (1-2s typical)
- ASB (Automatic Sensitivity Boost): Increases sensitivity after initial detection to prevent dropout due to high-bed vehicles
- Power: 12VDC…24VDC
- Operating current: 15 mA
- Operating temperature: -40°C…82°C (-40°F…180°F) 0…95% relative humidity
- Dimensions (L x W x H): 3.0”(76mm) x 0.9”(22mm) x 2.75”(70mm)
- Weight: 0.15 lbs. (68 g)
- Connector: 10-pin female
Vehicle Induction Loop Detection Video
Product Literature
- EMX ULTRA-PLG Spec Sheet
- EMX ULTRA-PLG Manual